Skip to content

Safety System Alarms ([SquibControlAlarm])

published Last Updated: Oct 9, 2026 HW: all
Applicable alarms (46)
CONTROL_FAILURECOMMUNICATION_FAILURETIMED_OUT_WAITING_FOR_POWER_FAILUREDRIVER_UNEXPECTED_SYSTEM_STATE_FAILUREDRIVER_UNEXPECTED_FEN_STATE_FAILUREBACKUP_POWER_FAILUREDRIVER_FAULT_STATUS_BIT_ASSERTEDDRIVER_POWER_FAILUREDRIVER_CLOCK_FAILUREDRIVER_OTP_CRC_FAILUREDIAGNOSTIC_TEST_FAILUREDIAGNOSTIC_TEST_TIMEOUT_FAILUREVRCM_TEST_FAILURELEAKAGE_TEST_FAILURESHORT_BETWEEN_LOOPS_TEST_FAILURECONTINUITY_CHECK_FAILUREFET_TEST_FAILURERESISTANCE_OUT_OF_RANGE_FAILURESQUIB_PORT_DEPLOYEDSQUIB_PORT_FAILUREUNEXPECTED_SQUIB_CONNECTIONWINCH_CUTTER_DEPLOYEDWINCH_CUTTER_DEPLOY_FAILUREwinch_cutter_state_changed0x0010028AZIP_EXECUTIVE_V4_WINCH_CUTTER_IN_TERMINAL_STATEREEFING_CUTTER_DEPLOY_FAILUREPARACHUTE_DEPLOY_FAILUREPARACHUTE_DEPLOYEDZIP_EXECUTIVE_CODE_PARACHUTE_STATE_NOT_AVAILABLEZIP_EXECUTIVE_CODE_PARACHUTE_STATE_NOT_DISABLEDZIP_EXECUTIVE_CODE_PARACHUTE_STATE_FAILEDZIP_EXECUTIVE_CODE_PARACHUTE_STATE_UNHANDLEDZIP_EXECUTIVE_V4_PARACHUTE_STATE_NOT_DISABLEDZIP_EXECUTIVE_V4_PARACHUTE_STATE_FAILEDZIP_EXECUTIVE_V4_PARACHUTE_STATE_DEPLOY_FAILEDZIP_EXECUTIVE_V4_PARACHUTE_STATE_CUTTING_FAILEDZIP_EXECUTIVE_V4_PARACHUTE_STATE_SUCCESSZIP_EXECUTIVE_V4_PARACHUTE_STATE_DEPLOYINGZIP_EXECUTIVE_V4_PARACHUTE_STATE_NOT_AVAILABLEZIP_EXECUTIVE_V4_PARACHUTE_STATE_UNHANDLEDREEFING_CUTTER_CONTROL_FAILUREWINCH_CUTTER_CONTROL_FAILUREPARACHUTE_CONTROL_FAILURERESISTANCE_OUT_OF_RANGECRITICAL_WORKFLOW_ERROR
Likely outcomes (1,040 missions, 2,377 issues) — click to expand

Based on 1,040 missions where this alarm fired in the last 90 days (for WINCH_CUTTER_DEPLOYED) as of 2026-10-13

Grounding vs discrepancy (of 2,377 ZERP issues filed on these missions)

Grounding 8% (191 of 2,377 issues) Discrepancy 92% (2,186 of 2,377 issues)

Top work orders

  • EV2: Inspect Aircraft after Droid Left Behind (DLB) · MAINTENANCE_ACTION 626
  • Inspect Droid after Droid Left Behind (DLB) · MAINTENANCE_ACTION 428
  • EV3: Inspect Aircraft after Droid Left Behind (DLB) · MAINTENANCE_ACTION 337
  • Reset Droid after DLB · REPAIR 291
  • V4 Zipping Point: Inspect Zipping Point after Droid Left Behind (DLB) - Ranger · MAINTENANCE_ACTION 157

Frequently replaced parts

Part P/N Removals
ASSY, SPOOL AND LINE, DOCKING FIN, AIRCRAFT, P2 48477 1,201
WINCH, ASSY, ZIP, P2 24078 304
DOCKING FIN WINCH ASSY, ZIP, P2 24084 165
PARALAND ASSY, DROID, P2 18427 126
LEFT DOOR ASSY, DROID, P2 21830 105

Frequently co-occurring alarms (% of the 1,040 missions above)

DROID_LEFT_BEHIND 99.8% of missions WINCH_MOTOR_DISABLED 97.9% of missions SQUIB_PORT_DEPLOYED 95.1% of missions WINCH_FREEWHEEL_LATCHED 14.8% of missions DROID_LEFT_BEHIND_IN_AUTOKIOSK 11.6% of missions

Aggregated from fleet operations and refreshed daily. Individual outcomes may vary by site and configuration.

Applicable to all hardware versions

Use this guide when a safety-system squib-control alarm, deployed state, or related CRITICAL_WORKFLOW_ERROR alarm report points to the Paraland, MGG, reefing cutter, winch cutter, distro, or squib driver.

We have generic alarms like CONTROL_FAILURE which are then paired with more specific information within the alarm reports of specific alarms such as RESISTANCE_OUT_OF_RANGE. Issues with the safety system are critical to root cause properly since this system ensures that our aircraft is able to safely deploy the parachute.

1 question
Which deployment signal is present? If winch_cutter_state_changed or ZIP_EXECUTIVE_V4_WINCH_CUTTER_IN_TERMINAL_STATE (0x0010028A) is the grounding signal, check the reported new state: it can indicate deployment or deploy failure.
Value Meaning
CONTROL_FAILURE The squib subsystem is unhealthy and cannot be trusted.
COMMUNICATION_FAILURE Cannot communicate with the squib driver IC.
TIMED_OUT_WAITING_FOR_POWER_FAILURE Timed out waiting for power to be ready.
DRIVER_UNEXPECTED_SYSTEM_STATE_FAILURE The squib driver reports unexpected system state.
DRIVER_UNEXPECTED_FEN_STATE_FAILURE The squib driver reports unexpected arming inputs, also known as FET Enable pins, state.
BACKUP_POWER_FAILURE Backup power or supercap failure.
DRIVER_FAULT_STATUS_BIT_ASSERTED The squib driver reports fault status bit asserted.
DRIVER_POWER_FAILURE The squib driver reports power failure.
DRIVER_CLOCK_FAILURE The squib driver reports clock failure.
DRIVER_OTP_CRC_FAILURE The squib driver reports OTP CRC failure.
DIAGNOSTIC_TEST_FAILURE Diagnostic test failed for any reason.
DIAGNOSTIC_TEST_TIMEOUT_FAILURE Diagnostic test is taking too long.
VRCM_TEST_FAILURE Voltage Regulator Current Monitor test failure.
LEAKAGE_TEST_FAILURE Leakage test failure.
SHORT_BETWEEN_LOOPS_TEST_FAILURE The test for short between loops failed.
CONTINUITY_CHECK_FAILURE Resistance on a squib channel is above 200 Ohm.
FET_TEST_FAILURE FET test failure.
RESISTANCE_OUT_OF_RANGE_FAILURE Measured resistance is out of range. Current firmware uses SQUIB_PORT_DEPLOYED instead when the port is marked deployed.
SQUIB_PORT_DEPLOYED Post-deployment continuity or resistance diagnostics indicate a port marked deployed; the alarm report names the squib channel.
SQUIB_PORT_FAILURE There is a fault on at least one of the squib ports.
UNEXPECTED_SQUIB_CONNECTION SPI failure during diagnostic setup or results.

Did this guide help you get unblocked?

Open suggestions

Open pull requests