BATTERY_UNSAFE_TO_CHARGE
This alarm is covered by this guide. Applicable alarms (1)
Likely outcomes — click to expand
Based on 252 missions where this alarm fired in the last 90 days as of 2026-10-13
Grounding vs discrepancy (of 102 ZERP issues filed on these missions)
Top work orders
- EV2 Zip Detailed Battery Inspection · TROUBLESHOOTING 22
- EV2/EV3 Perform Preflight Without Motors · INSPECTION 14
Frequently replaced parts
| Part | P/N | Removals |
|---|---|---|
| BATTERY ASSY, ZIP, P2 | 27158 | 119 |
| ASSY, SPOOL AND LINE, DOCKING FIN, AIRCRAFT, P2 | 48477 | 26 |
| TAIL ASM, STRBRD(RH), IM GNSS, ZIP, P2 | 0108359 | 20 |
| TAIL ASM, PORT(LH), OLD GEAR, ZIP, P2 | 0108336 | 20 |
| AFT MOTOR ASSY, ZIP, P2 | 23548 | 18 |
Frequently co-occurring alarms (% of the 252 missions above)
Aggregated from fleet operations and refreshed daily. Individual outcomes may vary by site and configuration.
Background
Section titled “Background”The Aircraft battery is not charging due to a battery fault. This may be a critical problem, or it may resolve on its own.
Troubleshooting Steps
Section titled “Troubleshooting Steps”graph TD
if-any-of-the-following-alarms-are-set["<small><b>Step 1</b></small><br/>Action: If any of the following alarms are se..."]
style if-any-of-the-following-alarms-are-set fill:#dcfce7,stroke:#22c55e,color:#14532d Hover or focus a block to preview it. Select the block to keep the preview open.
- AFE_TELEMETRY_TIMEOUT
- CHARGE_OVERTEMPERATURE
- CHARGE_UNDERTEMPERATURE
- HW_AFE_OVERTEMPERATURE
- HW_BRICK_OVERVOLTAGE_CRITICAL
- HW_BRICK_UNDERVOLTAGE_CRITICAL
- HW_CURRENT_SENSE_OPEN
- HW_INSTANTANEOUS_OVERCURRENT
- HW_PACK_OVERTEMPERATURE_CRITICAL
- HW_PACK_OVERVOLTAGE_CRITICAL
- HW_PACK_UNDERTEMPERATURE_WARNING
- HW_PACK_UNDERVOLTAGE_CRITICAL
- HW_SHUNT_OVERTEMPERATURE_CRITICAL
- HW_VBATT_OVERVOLTAGE_CRITICAL
- HW_VBATT_OVERVOLTAGE_WARNING
- HW_VBATT_UNDERVOLTAGE_CRITICAL
- HW_VBATT_UNDERVOLTAGE_WARNING
- SW_AFE_OVERTEMPERATURE
- SW_BRICK_IMBALANCE_CRITICAL
- SW_BRICK_IMBALANCE_WARNING
- SW_BRICK_OVERVOLTAGE_CRITICAL
- SW_BRICK_OVERVOLTAGE_WARNING
- SW_BRICK_UNDERVOLTAGE_CRITICAL
- SW_CHARGE_OVERCURRENT
- SW_EXTENDED_OVERCURRENT
- SW_INSTANTANEOUS_OVERCURRENT
- SW_PACK_OVERTEMPERATURE_CRITICAL
- SW_PACK_OVERTEMPERATURE_WARNING
- SW_PACK_OVERVOLTAGE_CRITICAL
- SW_PACK_OVERVOLTAGE_WARNING
- SW_PACK_UNDERTEMPERATURE_WARNING
- SW_PACK_UNDERVOLTAGE_CRITICAL
- SW_SHUNT_OVERTEMPERATURE_CRITICAL
- SW_SHUNT_OVERTEMPERATURE_WARNING
- CHARGE_UNDERTEMPERATURE
Resolution note
This plaintext block is ready to paste into the Resolution Note field on the ZERP issue you're working. The permalink below gives engineering review access to the full step-by-step timeline including any back-navigation; share it if the case needs a deeper look.
Permalink:
Session is too large to fit in a URL. Use Download session JSON to share the timeline out-of-band.
Did this guide help you get unblocked?
Open suggestions
There are no open suggestions.
Open pull requests
There are no open pull requests.