How to Approach a Paralanded Aircraft
Viewing this guide for
This alarm is covered by this guide. Use the flowchart below to determine how to approach an Aircraft after it has paralanded.

NOTE: Any attempt to offload logs and charge/discharge the battery should not be done until you can confirm ALL of the following:
- Cell temperatures are less than 60°C.
- The cell temperatures are not currently rising noticeably fast (example rate: ~1°C/min).
- Cell voltages are not imbalanced by more than 100 mV.
If ANY of the above is not true, escalate to engineering.
Log offloading can happen before the battery is discharged and taken off the Aircraft as the standard if no significant damage happened to the battery and telemetry can be monitored.
Did this guide help you get unblocked?
Open suggestions
There are no open suggestions.
Open pull requests